1. პროდუქტი დასრულდაview
The Juniper Networks QFX5100-48S-AFI is a highly flexible, high-performance Layer 3 switch designed to provide the foundation for modern data centers. It supports cloud and Software-Defined Networking (SDN) adoption, enabling rapid deployment and delivery of applications. This switch is a universal building block for data center switching architectures, offering diverse deployment options including fabric, Layer 3, and spine and leaf configurations, allowing easy adaptation to changing requirements.

სურათი 1: წინა view of the Juniper Networks QFX5100-48S-AFI Layer 3 Switch, showing the numerous SFP+ ports.
2. დაყენება და ინსტალაცია
This section provides general guidelines for setting up your Juniper Networks QFX5100-48S-AFI switch. For detailed rack mounting and cabling instructions, please refer to the official Juniper Networks documentation.
2.1 ფიზიკური მონტაჟი
- თაროზე მონტაჟი: The QFX5100-48S-AFI is designed for rack-mounting. Ensure proper rack space and ventilation.
- დენის კავშირი: Connect the power cords to the power supply units at the rear of the switch. This unit may have more than one power supply cord. CAUTION: Disconnect all power supply cords before servicing to avoid electric shock.
- Network Cabling: Connect your network cables (fiber optic SFP+ transceivers) to the front panel ports.

სურათი 2: უკანა view of the switch, highlighting the modular power supply units and fan modules. Note the "AIR OUT" labels on the fan modules, indicating airflow direction.

Figure 3: Close-up of the AC input warning label, indicating 100-240V~50-60Hz 4.5-2A input and a caution about disconnecting all power cords before servicing.
3. გადამრთველის მართვა
Once the switch is physically installed and powered on, it will begin its boot sequence. The front panel provides indicators for system status and port activity.
3.1 წინა პანელის ინდიკატორები
- სისტემის სტატუსის LED-ები: Monitor the ALM (Alarm), SYS (System), and MST (Master) LEDs for overall device health.
- Port Activity LEDs: Each SFP+ port has an associated LED that indicates link status and activity. A green light typically signifies an active link.

სურათი 4: მხარე view of the switch, showing mounting brackets and chassis design.

სურათი 5: მოპირდაპირე მხარე view of the switch, providing another perspective of its physical dimensions.
3.2 მართვის ინტერფეისები
The switch can be managed via its console port (CON), out-of-band management Ethernet port (C0), or in-band management through a configured network interface. The USB port can be used for software upgrades or configuration backups.

Figure 6: Close-up of the product label, showing SKU: QFX5100-48S-AFI, Serial Number (SN): TA3716510011, Part Number (PN): 650-064381 REV: 09, Manufacturing Date: 20161226, and MAC Address: 08:B2:58:C4:E0:00.

Figure 7: Close-up of the regulatory compliance label, indicating compliance with FCC Part 15, CE, UL, and other certifications. It also states "ASSEMBLED IN CHINA".
4. მოვლა
Regular maintenance ensures optimal performance and longevity of your QFX5100-48S-AFI switch.
- დასუფთავება: Keep the switch and its surroundings clean and free of dust. Use a soft, dry cloth for external cleaning. Do not use liquid cleaners.
- ჰაერის ნაკადი: Ensure that the air intake and exhaust vents are unobstructed to maintain proper cooling. The fan modules are designed for specific airflow directions (e.g., "AIR OUT").
- Firmware განახლებები: პერიოდულად შეამოწმეთ Juniper Networks-ის მხარდაჭერა website for the latest firmware updates to ensure security and performance enhancements.
- კომპონენტის გამოცვლა: Power supply units and fan modules are hot-swappable. Refer to the official documentation for safe replacement procedures.
5. Დიაგნოსტიკა
This section covers common issues and their potential solutions.
| პრობლემა | შესაძლო მიზეზი | გამოსავალი |
|---|---|---|
| ჩამრთველი არ ირთვება. | Power cords not connected or power supply failure. | Ensure all power cords are securely connected. Check power outlets. Verify power supply unit status LEDs. |
| პორტის LED ინდიკატორი გამორთულია. | No link, faulty cable, or incorrect transceiver. | Check cable connection at both ends. Replace cable. Verify transceiver compatibility and proper insertion. Check remote device status. |
| System Alarm LED (ALM) is lit. | Hardware fault, temperature issue, or power issue. | Check system logs for specific error messages. Ensure proper ventilation. Verify power supply status. Contact Juniper Networks support if the issue persists. |
6. სპეციფიკაციები
| ფუნქცია | დეტალი |
|---|---|
| მოდელის ნომერი | QFX5100-48S-AFI |
| ბრენდი | Juniper Networks |
| გადამრთველის ტიპი | მართული |
| პორტების რაოდენობა | 48 (SFP+) |
| გაფართოების სლოტები | 54 |
| ინტერფეისის ტიპი | PoE, SFP |
| საქმის მასალა | მეტალი |
| ფერი | რუხი |
| ნივთის წონა | 21.8 ფუნტი |
| პაკეტის ზომები | 36 x 24 x 12 ინჩი |
| მწარმოებელი | Juniper Networks, Inc. |
| პირველი ხელმისაწვდომი თარიღი | 24 წლის 2013 დეკემბერი |
| UPC | 832938068032 |
7. გარანტია და მხარდაჭერა
For detailed warranty information and technical support, please refer to the official Juniper Networks website or contact their customer service. Keep your product's serial number (found on the product label, e.g., TA3716510011) readily available when seeking support.
დამატებითი ინფორმაციისა და დახმარების რესურსების მოძიება შეგიძლიათ ოფიციალურ ვებგვერდზე Juniper Networks webსაიტი.