ბრენდი: PILZ

შესავალი

This manual provides essential information for the safe and effective use of the PILZ PNOZ S3 safety relay. The PNOZsigma safety relay is designed for monitoring safety functions in industrial applications, ensuring reliable operation of emergency stop buttons, safety gates, and light curtains.

Please read this manual thoroughly before installation, operation, or maintenance to ensure proper functionality and to prevent potential hazards.

უსაფრთხოების მნიშვნელოვანი ინფორმაცია

გაფრთხილება: This device must be installed and maintained by qualified personnel only. Failure to follow these instructions can result in serious injury or death.

პროდუქტი დასრულდაview

PILZ PNOZ S3 Safety Relay

Figure 1: PILZ PNOZ S3 Safety Relay

The PILZ PNOZ S3 is a compact safety relay designed for monitoring safety functions. Its narrow 17.5 mm width allows for space-saving installation in control cabinets.

ძირითადი მახასიათებლები:

  • 1/2-channel wiring with/without detection of shorts across contacts.
  • Manual or automatic start options.
  • 2 Normally Open (N/O) safety outputs and 1 auxiliary output (SC).
  • მოქმედი ტომიtage: 24 V DC.
  • Plug-in terminals of screw type for easy connection.
  • Monitoring capabilities for E-STOP, safety gates, and light guards.

სურათის აღწერა: მხარე view of the PILZ PNOZ S3 safety relay, showcasing its distinctive yellow and black housing. The top section features two sets of terminals, labeled 'EX' and 'LX', indicating expansion and input connections. Below these, a row of terminals is visible, marked 'A1', '13', '23', 'S12', 'S22', and 'S34', which are typically used for power supply and safety inputs. The side panel of the unit clearly displays the product name 'PILZ PNOZ S3' and a vertical array of indicator lights. These lights are labeled 'Power', 'In1', 'In2', 'Out', 'Start', and 'Fault', providing visual feedback on the relay's operational status. At the bottom, another set of terminals is present, labeled 'S11', 'S21', 'Y32', 'A2', '14', and '24', which are typically for safety outputs and auxiliary connections. The overall design emphasizes a compact, industrial-grade construction with clear labeling for ease of installation and monitoring.

დაყენება და ინსტალაცია

მონტაჟი

The PNOZ S3 is designed for DIN rail mounting. Ensure the mounting surface is stable and free from excessive vibration. Mount the device vertically to ensure proper heat dissipation.

გაყვანილობა

Use appropriate wire gauges for all connections. The device features plug-in screw-type terminals for secure wiring. Refer to the terminal designations on the device for correct connections.

Ensure all connections are tight and secure to prevent intermittent operation or safety hazards.

ოპერაცია

საწყისი ჩართვა

After completing all wiring and verifying connections, apply power to the device. The "Power" indicator light should illuminate.

ინდიკატორის ნათურები

Table 1: Indicator Light Status
ინდიკატორისტატუსიაღწერა
ძალაუფლებამწვანე (ჩართული)მოწყობილობა ჩართულია.
In1, In2მწვანე (ჩართული)Safety inputs are closed (e.g., E-STOP released, safety gate closed).
გარეთმწვანე (ჩართული)Safety outputs are active (relay contacts closed).
დაწყებამწვანე (ჩართული)Start condition met (e.g., start button pressed, automatic start enabled).
ბრალიაRed (ON/Flashing)Indicates an internal fault or wiring error. Refer to troubleshooting.

Starting the Safety Function

Once all safety inputs are closed (In1, In2 lights are green), the device is ready to be started. Depending on the configuration:

To stop the safety function, activate a safety input (e.g., press E-STOP, open safety gate). The "Out" light will extinguish, and the safety outputs will de-energize.

მოვლა

The PILZ PNOZ S3 safety relay is designed for minimal maintenance. However, regular inspections are recommended to ensure continued safe operation.

All maintenance and testing should be performed by qualified personnel.

პრობლემების მოგვარება

This section provides guidance for common issues. For complex problems, contact PILZ technical support.

ცხრილი 2: პრობლემების აღმოფხვრის გზამკვლევი
პრობლემაშესაძლო მიზეზიგამოსავალი
"Power" light is off.არ არის კვების წყარო ან არასწორი ძაბვაtage.Check 24 V DC power supply to terminals A1/A2. Verify voltage.
"In1" or "In2" light is off when inputs should be closed.Open safety input circuit (e.g., E-STOP pressed, safety gate open, wiring error).Check continuity of safety input devices and wiring to S12, S22, S34. Ensure all safety devices are in their safe (closed) state.
"Out" light does not illuminate after start attempt.Safety inputs not closed, start condition not met, or internal fault.Verify "In1" and "In2" lights are green. If manual start, ensure start button is pressed and "Start" light illuminates. Check "Fault" light.
"Fault" light is red.Internal device fault, short circuit in input wiring, or incorrect wiring.Disconnect power, re-check all wiring according to the manual. If fault persists, the device may be defective.

სპეციფიკაციები

ცხრილი 3: ტექნიკური მახასიათებლები
პარამეტრიღირებულება
მოდელიPNOZ S3 24VDC (750103)
შეყვანები1/2-channel wiring with/without detection of shorts across contacts
დაწყების ოფციებისახელმძღვანელო / ავტომატური
უსაფრთხოების შედეგები2 N/O (Normally Open)
დამხმარე საშუალებები1 SC (Signaling Contact)
მიწოდება ტომიtage24 V DC
სიგანე17.5 მმ
ტერმინალებიPlug-in screw type
მონიტორინგის ფუნქციებიE-STOP, უსაფრთხოების ჭიშკარი, მსუბუქი მცველი
ნივთის წონა0.01 უნცია
კონექტორის ტიპიდანამატი
საკონტაქტო მასალანიკელი
კონტაქტის ტიპიჩვეულებრივ ღიაა
სამონტაჟო ტიპიშეერთება მთაზე

საგარანტიო ინფორმაცია

Specific warranty terms for the PILZ PNOZ S3 safety relay are provided by the manufacturer, PILZ. Please refer to the warranty documentation included with your purchase or visit the official PILZ website for detailed information regarding warranty coverage, duration, and conditions.

შეინახეთ შეძენის დამადასტურებელი საბუთი გარანტიასთან დაკავშირებული ნებისმიერი პრეტენზიისთვის.

ტექნიკური მხარდაჭერა

For technical assistance, product inquiries, or support regarding the PILZ PNOZ S3 safety relay, please contact PILZ directly.

When contacting support, please have your product model (PNOZ S3 24VDC) and any relevant error messages or observations ready.