Trane VAL12000

Trane VAL12000 OEM Thermostatic Expansion Valve

მოდელი: VAL12000 / VAL-12000

ბრენდი: ტრენე

1. პროდუქტი დასრულდაview

The Trane VAL12000 / VAL-12000 is an Original Equipment Manufacturer (OEM) thermostatic expansion valve designed for use in various Trane chiller systems. This component plays a crucial role in the refrigeration cycle by controlling the amount of refrigerant flowing into the evaporator, ensuring efficient heat exchange and system performance.

It is a direct replacement for or supersedes models VAL-12000, VAL012000, VAL08573, VAL-8573, and VAL8573.

Trane OEM კომპონენტების ქ.amp

Figure 1: Illustrative stamp indicating Trane OEM Component. Actual product appearance may vary.

Commonly Used In:

  • Various Trane Chillers: Rotary Chillers, RTAC Chillers, BCVC Chillers
  • Specific Rotary Chiller Models: RTAC120, RTAC135, RTAC140, and others.

2. სპეციფიკაციები

მწარმოებელიტრენე
ნაწილის ნომერიVAL12000
საქონლის მოდელის ნომერიVAL12000
სარქვლის ტიპითერმოსტატული გაფართოების სარქველი (TXV)
კავშირები1.387 ODS (Outlet Diameter Size) x 2.125 OD (Overall Diameter); M12 Input
ნივთის წონადაახლოებით 5 ფუნტი
საქონლის პაკეტის რაოდენობა1
ASINB07ZWHPJS6
პირველი ხელმისაწვდომი თარიღი1 წლის 2019 ნოემბერი

შენიშვნა: სპეციფიკაციები შეიძლება შეიცვალოს წინასწარი შეტყობინების გარეშე. ყველაზე ზუსტი ინფორმაციისთვის ყოველთვის იხილეთ პროდუქტის ეტიკეტი.

3. ინსტალაციის სახელმძღვანელო

Installation of the Trane VAL12000 expansion valve should only be performed by qualified HVAC technicians. Improper installation can lead to system malfunction, refrigerant leaks, and potential safety hazards. Always follow industry best practices and local codes.

3.1 უსაფრთხოების ზომები

  • Ensure the system is de-energized and depressurized before beginning any work.
  • Wear appropriate Personal Protective Equipment (PPE), including safety glasses and gloves.
  • Handle refrigerants with care, following all safety guidelines.
  • უზრუნველყოს სათანადო ვენტილაცია სამუშაო ზონაში.

3.2 ინსტალაციის ნაბიჯები (ზოგადი)

  1. სისტემის მომზადება: Isolate the section of the refrigeration system where the valve is to be installed. Recover any refrigerant according to environmental regulations.
  2. ძველი სარქვლის ამოღება: Carefully disconnect and remove the existing expansion valve, noting its orientation and connections.
  3. Prepare New Valve: Inspect the new VAL12000 valve for any damage. Ensure all connection points are clean and free of debris.
  4. სარქვლის შეერთება: Install the new valve, ensuring proper alignment and secure connections. Use appropriate brazing or flaring techniques as required by the system design. Pay close attention to the M12 input and ODS connections.
  5. Thermal Bulb Placement: Securely attach the thermal bulb to the suction line in the correct location, typically just after the evaporator outlet, ensuring good thermal contact. Insulate the bulb to prevent ambient temperature interference.
  6. გაჟონვის შემოწმება: After installation, perform a thorough leak check using an appropriate leak detection method.
  7. ევაკუაცია და დატენვა: Evacuate the system to a deep vacuum to remove non-condensables and moisture. Recharge the system with the correct type and amount of refrigerant as specified by the chiller manufacturer.
  8. სისტემის გაშვება: Slowly bring the system back online and monitor its performance to ensure proper operation of the expansion valve.

For detailed, system-specific installation instructions, refer to the service manual of the Trane chiller unit in which this valve is being installed.

4. ოპერაცია

The Trane VAL12000 is a thermostatic expansion valve (TXV) that automatically regulates the flow of liquid refrigerant into the evaporator based on the superheat of the refrigerant vapor leaving the evaporator. Its primary function is to maintain a constant superheat, ensuring the evaporator is fully utilized without allowing liquid refrigerant to return to the compressor.

The thermal bulb, sensing the temperature of the suction line, transmits pressure to the diaphragm within the valve. This pressure, balanced against the evaporator pressure and spring pressure, modulates the valve's opening. This dynamic control optimizes system efficiency and protects the compressor from liquid slugging.

5. მოვლა

The Trane VAL12000 expansion valve is a robust component designed for long-term reliability. While it generally requires minimal direct maintenance, its optimal performance is dependent on the overall health and cleanliness of the refrigeration system.

5.1 Recommended Practices

  • სისტემის სისუფთავე: Ensure the refrigeration system remains free of contaminants (moisture, acids, debris) which can cause corrosion or blockages within the valve. Regular filter dryer replacement is crucial.
  • Refrigerant Quality: Use only the specified type and quality of refrigerant.
  • შესრულების მონიტორინგი: Periodically monitor system superheat and subcooling. Deviations can indicate issues with the expansion valve or other system components.
  • გაჟონვის გამოვლენა: Regularly check for refrigerant leaks around valve connections.

Any adjustments or repairs to the expansion valve or refrigeration system should be performed by certified HVAC professionals.

6. Დიაგნოსტიკა

Troubleshooting issues related to an expansion valve often involves diagnosing overall system performance. The following are common symptoms that might indicate an issue with the expansion valve, though they can also be caused by other system components.

სიმპტომიPossible Cause (Valve Related)მოქმედება
High Superheat / Low Suction PressureValve restricted or stuck closed; thermal bulb lost charge or improperly installed.Check thermal bulb contact and insulation. Inspect valve for blockages. Consider valve replacement if faulty.
Low Superheat / High Suction Pressure (Flooding)Valve stuck open; thermal bulb improperly installed or sensing incorrect temperature.Verify thermal bulb placement. Check for external bulb damage. Consider valve replacement if faulty.
Fluctuating Suction Pressure / SuperheatIntermittent valve operation; moisture in system causing ice formation at valve orifice.Check for system contaminants. Replace filter dryer. Evacuate and recharge system.
Compressor Short CyclingImproper refrigerant flow due to valve issue, leading to low pressure cutout.Diagnose refrigerant charge and valve operation.

მნიშვნელოვანია: Troubleshooting refrigeration systems requires specialized knowledge and tools. Always consult with or hire a qualified HVAC technician for diagnosis and repair.

7. გარანტია და მხარდაჭერა

As an OEM component, the Trane VAL12000 expansion valve is typically covered under the warranty terms provided by Trane for their chiller systems or by the distributor from whom it was purchased. Specific warranty details, including duration and coverage, may vary.

For warranty claims, technical support, or to order replacement parts (such as MOD02686 for a stepper motor or MOD02688 for a cable, if applicable to your system), please contact your authorized Trane distributor or a certified HVAC service provider.

მწარმოებელი: ტრენე

კონტაქტი: Refer to your local Trane representative or the official Trane website for service and support information.

დაკავშირებული დოკუმენტები - VAL12000

წინასწარიview Trane RTWD/RTUD R'ewal Service Program Kit-ის ინსტალაციის ინსტრუქცია
RTWD და RTUD გამაგრილებლებისთვის განკუთვნილი Trane R'ewal Service Program Kit-ის ინსტალაციის ინსტრუქციები, ნაწილების განლაგების დეტალური აღწერა, უსაფრთხოების გაფრთხილებები, გარემოსთან დაკავშირებული პრობლემები და კომპონენტების გაუმართაობა.
წინასწარიview Trane-ის ყოვლისმომცველი გაცივებული წყლის სისტემის დიზაინის კატალოგი
Trane-ის ყოვლისმომცველი კატალოგი გაცივებული წყლის მოწინავე სისტემების დიზაინისთვის. ეს სახელმძღვანელო დეტალურად აღწერს სისტემის კომპონენტებს, თანამედროვე დიზაინის პრინციპებს, კონფიგურაციებს და შერჩევის კრიტერიუმებს გამაგრილებლების, გაგრილების კოშკების, ტუმბოების და მართვის სარქველებისთვის. იგი ფოკუსირებულია კომერციულ და სამრეწველო HVAC აპლიკაციებში ეფექტურობის, საიმედოობისა და ეკონომიურობის მიღწევაზე, მათ შორის Tracer-ის გაცივებული ქარხნის კონტროლისა და Trane Design Assist-ის შესახებ ინფორმაციას.
წინასწარიview Trane AFDR-ის რეტროფიტის ინსტალაციის ინსტრუქციები RTHD გამაგრილებლებისთვის
RTHD გამაგრილებელი მოწყობილობებისთვის განკუთვნილი Trane AFDR Retrofit Air-cooled Adaptive Frequency Drive™-ის ყოვლისმომცველი ინსტალაციის სახელმძღვანელო. მოიცავს უსაფრთხოებას, გარემო პირობებს, მოდელის დეტალებს და კვალიფიციური პერსონალისთვის ეტაპობრივ ინსტალაციის პროცედურებს.
წინასწარიview Trane Ignitor-ის დაყენების ინსტრუქციები KIT03033USA
Trane-ის ანთების მოწყობილობის KIT03033USA დეტალური ინსტალაციის ინსტრუქციები, რომლებიც მოიცავს უსაფრთხოების გაფრთხილებებს, გარემოსდაცვით მოსაზრებებს და კვალიფიციური პერსონალისთვის ეტაპობრივ პროცედურებს.
წინასწარიview Trane Air-Fi™ უსადენო კომუნიკაციის სენსორის (WCS) მოკლე სახელმძღვანელო
ეს სახელმძღვანელო გთავაზობთ Trane Air-Fi™ უსადენო კომუნიკაციის სენსორის (WCS) შესახებ სწრაფ საცნობარო ინფორმაციას, სადაც დეტალურად არის აღწერილი, თუ როგორ დაარეგულიროთ ოთახის ტემპერატურა, სისტემის პარამეტრები, ვენტილატორის სიჩქარე, მართოთ დატვირთვის დონე და გაიგოთ შეცდომის კოდები. ის მოიცავს უსაფრთხოების გაფრთხილებებს და ბატარეის მუშაობის ინდიკატორებს.
წინასწარიview Trane-ის შენობის ავტომატიზაციის სისტემის (BAS) და HVAC კომპონენტების ფასების სია
Comprehensive price list for Trane Building Automation Systems (BAS), HVAC equipment, and related components, including controllers, sensors, chillers, air handlers, and accessories. Details product codes, model numbers, and pricing for commercial and industrial applications.