PowerWalker 10122182

PowerWalker VFI 3000 AT UPS User Manual

მოდელი: 10122182

შესავალი

The PowerWalker VFI AT series is an online Uninterruptible Power Supply (UPS) system designed to provide reliable power protection for critical electronic devices. This manual provides essential information for the safe and efficient operation of your PowerWalker VFI 3000 AT UPS, model 10122182.

უსაფრთხოების მნიშვნელოვანი ინსტრუქციები

Please read and follow all instructions carefully before installing, operating, or servicing the UPS. Keep this manual for future reference.

პაკეტის შიგთავსი

Verify that all items listed below are included in your package. If any items are missing or damaged, contact your dealer.

პროდუქტი დასრულდაview

წინა პანელი

წინა view of PowerWalker VFI 3000 AT UPS with display and control buttons.

სურათი 1: წინა view of the PowerWalker VFI 3000 AT UPS. This image displays the main chassis, ventilation grilles, and the front control panel with its LCD screen and buttons.

Close-up of PowerWalker VFI 3000 AT UPS front panel showing LCD and buttons.

სურათი 2: დეტალურად view of the UPS front panel. The LCD screen shows input/output voltage and load status. Below the screen are control buttons: ON, OFF, ENTER, and ESC, used for navigating menus and controlling the unit.

The front panel features an LCD display that provides real-time information about the UPS status, including input/output voltage, battery level, and load capacity. Control buttons allow for navigation through the display menus and basic operation of the unit.

უკანა პანელი

უკანა view of PowerWalker VFI 3000 AT UPS showing power outlets, communication ports, and fans.

სურათი 3: უკანა view of the PowerWalker VFI 3000 AT UPS. This panel includes multiple Type F earthing contact outlets for connecting protected devices, cooling fans, a main power input, and communication ports (USB, RS-232, and an optional slot for network card).

The rear panel provides the necessary connections for input power, output to protected devices, and communication interfaces. It includes four Type F earthing contact outlets, a terminal output, USB and RS-232 communication ports, and slots for optional accessories like network cards.

დაყენების ინსტრუქციები

1. დასაქმების

2. დენის დაკავშირება

  1. Connect the provided power input cable to the UPS input receptacle on the rear panel.
  2. Plug the other end of the power input cable into a grounded wall outlet.
  3. Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery performance.

3. მოწყობილობების დამაკავშირებელი

  1. Plug your critical devices (e.g., computers, servers, network equipment) into the Type F output receptacles on the rear panel of the UPS.
  2. Ensure that the total load connected to the UPS does not exceed its rated capacity (2700W for this model).
  3. For devices requiring terminal output, connect them according to electrical safety standards.

4. საწყისი გაშვება

  1. After connecting the UPS to AC power and allowing initial charging, press and hold the ON button on the front panel for approximately 2 seconds.
  2. The UPS will perform a self-test, and the LCD display will illuminate, indicating operational status.
  3. The UPS is now providing protected power to the connected devices.

UPS-ის ოპერირება

ჩართვა/გამორთვა

LCD დისპლეის გაგება

The LCD display provides critical information about the UPS status. Use the ENTER და ESC buttons to navigate through different display screens, which may include:

ბატარეის სარეზერვო ოპერაცია

ძალაუფლების ოუtage ან მნიშვნელოვანი მოცულობაtage fluctuation, the UPS will automatically switch to battery power to provide continuous power to connected devices. An audible alarm may sound, and the LCD will indicate "Battery Mode." The duration of battery backup depends on the load connected and the battery charge level.

საკომუნიკაციო პროგრამული უზრუნველყოფა

For advanced monitoring and management, install the provided communication software on a computer connected to the UPS via the USB or RS-232 port. This software allows for scheduled shutdowns, remote monitoring, and detailed event logging.

მოვლა

ბატარეის მოვლა

დასუფთავება

შენახვა

პრობლემების მოგვარება

Refer to the table below for common issues and their solutions. If the problem persists, contact technical support.

პრობლემაშესაძლო მიზეზიგამოსავალი
UPS არ ირთვება.No AC input power.
დაბალი ბატარეის დატენვა.
შეამოწმეთ დენის კაბელის შეერთება და კედლის სოკეტი.
Allow UPS to charge for several hours.
UPS ნორმალურ რეჟიმში განუწყვეტლივ აჟღერებს სიგნალს.გადატვირთვის მდგომარეობა.
შინაგანი ბრალი.
Reduce the load by unplugging non-essential devices.
დაუკავშირდით ტექნიკურ მხარდაჭერას.
მოკლე სარეზერვო დრო.ბატარეები სრულად არ არის დამუხტული.
Batteries reaching end of life.
გადაჭარბებული დატვირთვა.
Allow UPS to charge for 8+ hours.
Contact service for battery replacement.
შეამცირეთ დაკავშირებული დატვირთვა.
UPS is noisy.Normal fan operation (especially under load).
ვენტილატორის ხელის შეშლა.
This is normal for online UPS units. Ensure proper ventilation.
Check for and clear any obstructions around fans.

სპეციფიკაციები

ფუნქციადეტალი
მოდელი10122182
ტევადობა3000 VA / 2700 W
შეყვანის მოცულობაtage300 Volts (nominal)
გამოყვანის ტომიtage300 Volts (nominal)
ბატარეის ტიპიLead-Acid, AGM
მოყვება ბატარეებიდიახ
გამომავალი განყოფილებები4x Type F Earthing Contact, Terminal Output
ფორმის ფაქტორიკოშკი
ზომები (L x W x H)41.6 x 19.6 x 34.2 სმ
წონა21 კგ
მასალაპლასტიკური
Ampგაბრაზება9 Amps

გარანტია და მხარდაჭერა

The PowerWalker VFI 3000 AT UPS is covered by a manufacturer's warranty. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official PowerWalker webსაიტი.

For technical support, service inquiries, or to report any issues, please contact your local dealer or PowerWalker customer service. Have your model number (10122182) and purchase information ready when contacting support.