Renogy SUNDCCB160MC2P

რენოგი სანტრი 160 Amp 2-პოლური DC ამომრთველის ინსტრუქციის სახელმძღვანელო

Model: SUNDCCB160MC2P

1. პროდუქტი დასრულდაview

The Suntree DC Molded Case Circuit Breaker is engineered to safeguard DC electrical installations from overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms for reliable protection. Upon detecting a fault, the circuit breaker automatically interrupts the electrical circuit, preventing wire damage and reducing fire risk. This device can also be manually opened under its full rated load for electrical maintenance without sustaining damage. Designed for reversible connection, the circuit breaker can be wired in either direction and supports bidirectional current flow. Clear markings on the handle indicate the contact position (ON/OFF) at a glance. Its design facilitates easy installation on both standard DIN rails and vertical surfaces.

რენოგი სანტრი 160 Amp 2-Pole DC Circuit Breaker

Figure 1: Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

2. უსაფრთხოების ინფორმაცია

  • ამომრთველის დამონტაჟებამდე ან მომსახურებამდე ყოველთვის გამორთეთ ელექტროენერგია.
  • Installation should be performed by qualified personnel in accordance with local electrical codes and standards.
  • Ensure proper wire sizing and terminal connections to prevent overheating.
  • არ ჩართოთ ავტომატური ამომრთველი, თუ ის დაზიანებული ჩანს.
  • ელექტრო სისტემებთან მუშაობისას გამოიყენეთ შესაბამისი პირადი დამცავი აღჭურვილობა (PPE).

3. მონტაჟი

3.1 პაკეტის შიგთავსი

  • 160A 2P DC Molded Case Circuit Breaker
  • სამონტაჟო ხრახნები
  • Insulation Barrier (2 pieces)
Dimensions and included components of the circuit breaker

Figure 2: Product Dimensions and Included Components

3.2 მონტაჟი

The circuit breaker supports both DIN rail and vertical surface mounting. Ensure the mounting location is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.

Diagram showing quick installation on DIN rail with insulation barriers

Figure 3: Quick Installation on DIN Rail

3.3 გაყვანილობის კავშირები

Connect the DC positive and negative cables to the corresponding terminals on the circuit breaker. The circuit breaker is designed for reversible connection and functions with bidirectional current. Ensure all connections are secure and tight. Install the provided insulation barriers between terminals for enhanced safety.

Wiring diagram showing positive and negative connections to the circuit breaker

სურათი 4: კავშირის დიაგრამა

3.4 Sizing Tips for Circuit Breaker Selection

Proper sizing is crucial for effective protection.

  • For controller/inverter/DC device:
    1. Determine the maximum continuous operating current (current = watt/voltagდა).
    2. Calculate maximum current = 1.25 x maximum continuous operating current.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
  • For solar panel:
    1. Determine the short-circuit current.
    2. Calculate maximum current = Short-circuit current x 1.25 x 1.25.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
Diagram illustrating sizing tips for circuit breakers in solar systems

Figure 5: Circuit Breaker Sizing Guidelines

4. ოპერაცია

4.1 ჩართვა/გამორთვა

To switch the circuit breaker ON, push the handle to the 'ON' position. To switch it OFF, push the handle to the 'OFF' position. The handle's position clearly indicates the contact status.

Image showing the ON and OFF positions of the circuit breaker handle

Figure 6: ON/OFF Markings

4.2 Protection Mechanisms

The circuit breaker provides protection against both overload and short-circuit conditions. In the event of an electrical fault, the breaker will automatically trip to protect the system.

Diagram illustrating overload and short-circuit protection features

Figure 7: Overload and Short-circuit Protection

5. მოვლა

After the circuit breaker has tripped due to a fault, it can be reset manually. No damage occurs to the breaker itself from tripping. Regular visual inspection for any signs of wear or damage is recommended. Ensure connections remain tight.

Diagram showing mechanical and electrical life cycles, and high electrical conductivity

Figure 8: Durability and Conductivity

6. Დიაგნოსტიკა

  • Breaker trips frequently: This indicates an overload or short circuit in the system. Identify and resolve the underlying electrical issue before resetting the breaker.
  • Breaker does not reset: Ensure the fault condition has been cleared. If the breaker still does not reset, it may be damaged and require replacement.
  • No power after installation: Verify all wiring connections are correct and secure. Check for proper input voltage and ensure the breaker is in the 'ON' position.

7. სპეციფიკაციები

ფუნქციასპეციფიკაცია
ბრენდირენოგი
მიმდინარე რეიტინგი160 Amps
ამომრთველის ტიპისტანდარტული
სამონტაჟო ტიპიზედაპირის მთა
პოლონელების რაოდენობა2
UPC810009719694
მწარმოებელირენოგი
ნაწილის ნომერიSUNDCCB160MC2P
ნივთის წონა5.15 ფუნტი
პროდუქტის ზომები7.9 x 3.5 x 5.3 ინჩი
მასალასპილენძი
მოყვება კომპონენტები160A 2P DC Molded Case Circuit Breaker, Mounting Screws, Insulation Barrier

8. გარანტია და მხარდაჭერა

Renogy offers a 1-year material and workmanship warranty for this product. For technical support or warranty claims, please visit the official Renogy webსაიტზე ან დაუკავშირდით მათ მომხმარებელთა მომსახურებას.

დამატებითი ინფორმაციისთვის ეწვიეთ რენოგის მაღაზია.

დაკავშირებული დოკუმენტები - SUNDCCB160MC2P

წინასწარიview Renogy-ის ქსელიდან გამორთული მზის ენერგიის ნაკრების ზოგადი ინსტრუქცია: ინსტალაციისა და ექსპლუატაციის სახელმძღვანელო
ეს სახელმძღვანელო შეიცავს ყოვლისმომცველ ინსტრუქციებს Renogy-ის ქსელიდან გამორთული მზის ენერგიის ნაკრების მონტაჟის, გაყვანილობისა და მოვლა-პატრონობის შესახებ. გაეცანით უსაფრთხოების ზომებს, სამონტაჟო სისტემებს, აკუმულატორების კონფიგურაციებს და სისტემის კავშირებს საიმედო ქსელიდან გამორთული ენერგიის მისაღებად.
წინასწარიview Renogy-ის ქსელიდან გამორთული მზის ენერგიის ნაკრების მომხმარებლის სახელმძღვანელო: ინსტალაციის, გაყვანილობისა და მონტაჟის სახელმძღვანელო
Renogy-ის ქსელიდან გამორთული მზის ენერგიის კომპლექტების ყოვლისმომცველი მომხმარებლის სახელმძღვანელო, რომელიც მოიცავს მონტაჟს, გაყვანილობას, სამონტაჟო სისტემებს (Z-სამაგრი, რელსი, ბოძი), აკუმულატორების კონფიგურაციას, უსაფრთხოების ზომებს და ANL დაუკრავენის გამოყენებას RV-ებისთვის, ნავებისთვის და ქსელიდან გამორთული ენერგოსისტემებისთვის.
წინასწარიview Renogy Battery Shunt 300 მომხმარებლის სახელმძღვანელო
Renogy Battery Shunt 300-ის ყოვლისმომცველი მომხმარებლის სახელმძღვანელო, რომელიც შეიცავს ინსტალაციის, ექსპლუატაციის, კონფიგურაციისა და პრობლემების მოგვარების ინსტრუქციებს მზის და ელექტროგადამცემ სისტემებში ინტელექტუალური ბატარეის მონიტორინგისთვის.
წინასწარიview Renogy ONE Core-ის მოკლე სახელმძღვანელო | ინსტალაცია და ექსპლუატაცია
Renogy ONE Core-ის (RSHGWSN-W02W-G3) მოკლე სახელმძღვანელო, რომელიც მოიცავს ინსტალაციას, შეერთებას და ძირითად მუშაობას. შეიტყვეთ, თუ როგორ დააყენოთ თქვენი Renogy ONE Core ოპტიმალური მუშაობისთვის.
წინასწარიview Renogy BT-2 Bluetooth მოდულის მომხმარებლის სახელმძღვანელო და ტექნიკური მახასიათებლები
Renogy BT-2 Bluetooth მოდულის ყოვლისმომცველი სახელმძღვანელო, სადაც დეტალურად არის აღწერილი მისი მახასიათებლები, ნაწილების იდენტიფიკაცია, მუშაობა, ტექნიკური მახასიათებლები და მზის ენერგიის დამუხტვის კონტროლერების აპლიკაციასთან დაკავშირება.
წინასწარიview Renogy ONE-ის ძირითადი მომხმარებლის სახელმძღვანელო: ენერგიის მონიტორინგისა და ჭკვიანი სახლის ინტეგრაციის ყოვლისმომცველი სახელმძღვანელო
ეს მომხმარებლის სახელმძღვანელო შეიცავს დეტალურ ინსტრუქციებს Renogy ONE Core-ისთვის, რომელიც მოიცავს ინსტალაციას, ექსპლუატაციას, ისეთ ფუნქციებს, როგორიცაა RV-ს დონის რეგულირება და ჭკვიანი სახლის ინტეგრაცია, პრობლემების მოგვარებას და ტექნიკურ სპეციფიკაციებს. შეიტყვეთ, თუ როგორ აკონტროლოთ და მართოთ თქვენი ენერგოსისტემები ეფექტურად.