1. პროდუქტი დასრულდაview
The Trane Control Limit 220F is a genuine OEM (Original Equipment Manufacturer) part designed for commercial HVAC units. This component functions as a temperature limit control, ensuring the safe operation of heating and cooling systems by preventing temperatures from exceeding a specified threshold of 220°F.
It is crucial to use genuine OEM parts for safety, reliability, and optimal performance of your Trane HVAC equipment.
1.1. რა არის ყუთში
- Replacement Part (Trane Control Limit 220F)
1.2. პროდუქტის მახასიათებლები
- ორიგინალი OEM ნაწილი: Ensures compatibility and reliability with Trane HVAC systems.
- ტემპერატურის ლიმიტის კონტროლი: Designed to activate at 220°F to prevent overheating.
- გამძლე კონსტრუქცია: Built to withstand the demands of commercial HVAC environments.
- მარტივი ინტეგრაცია: Designed for straightforward replacement in compatible Trane units.

სურათი 1.1: წინა view of the Trane Control Limit 220F, showing the metallic disc, mounting bracket, orange wires, and white electrical connector.
2. უსაფრთხოების ინფორმაცია
გაფრთხილება: Always disconnect power to the HVAC unit before attempting any installation, maintenance, or repair. Failure to do so can result in serious injury or death from electrical shock.
- Installation should only be performed by qualified HVAC technicians or licensed electricians.
- გამოიყენეთ შესაბამისი პირადი დამცავი აღჭურვილობა (PPE), მათ შორის დამცავი სათვალე და ხელთათმანები.
- დარწმუნდით, რომ ყველა სადენიანი შეერთება უსაფრთხოა და შეესაბამება ადგილობრივ ელექტრო კოდებს.
- Do not bypass or modify the limit control. It is a critical safety device.
- Refer to the specific HVAC unit's service manual for detailed wiring diagrams and safety procedures.
3. დაყენება და ინსტალაცია
This section provides general guidelines for installing the Trane Control Limit 220F. Always refer to the specific service manual for your Trane HVAC unit for precise installation instructions and wiring diagrams.
3.1. საჭირო ხელსაწყოები
- ხრახნების ნაკრები (ფილიპსის და ბრტყელთავიანი)
- Wire strippers/cutters (if new wiring is needed)
- Multimeter (for testing continuity and voltage)
- პირადი დამცავი მოწყობილობა (PPE)
3.2. ინსტალაციის ეტაპები
- გამორთეთ ელექტროენერგია: Locate the main power switch for the HVAC unit and turn it OFF. Verify power is off using a multimeter.
- წვდომის კომპონენტი: Open the access panel of the HVAC unit to locate the existing limit control.
- დოკუმენტის გაყვანილობა: Before disconnecting, take a photograph or make a diagram of the existing wiring connections to the limit control. This will aid in correct re-installation.
- ძველი კომპონენტის წაშლა: Carefully disconnect the wires from the old limit control and unmount it from its position.
- ახალი კომპონენტის ინსტალაცია: Mount the new Trane Control Limit 220F in the same location as the old one. Ensure it is securely fastened.
- გაყვანილობის დაკავშირება: Connect the wires to the new limit control according to your documented diagram. Ensure all connections are tight and secure. The white connector should snap firmly into place.
- უსაფრთხო წვდომის პანელი: Close and secure the HVAC unit's access panel.
- დენის აღდგენა და ტესტირება: Restore power to the HVAC unit. Perform system checks to ensure the unit operates correctly and the limit control functions as expected.

სურათი 3.1: ზედა view of the Trane Control Limit 220F, showing the compact arrangement of the orange wires and the white connector, ready for installation.

სურათი 3.2: მხარე view of the Trane Control Limit 220F, highlighting the metallic disc and the points where the orange wires connect to the control unit.
4. ოპერაცია
The Trane Control Limit 220F is a safety device designed to monitor the temperature within the HVAC system. Its primary function is to open an electrical circuit if the temperature exceeds 220°F, thereby shutting down the heating element or other components to prevent damage or hazardous conditions.
- Under normal operating conditions, the limit control allows electrical current to pass through, enabling the HVAC unit to function.
- If the internal temperature of the monitored area reaches or exceeds 220°F, the bimetallic disc within the control will deform, opening the electrical contacts.
- Once the contacts open, power to the heating component (or other controlled device) is interrupted, causing the unit to shut down.
- The control typically resets automatically once the temperature drops below the limit, allowing the system to restart if the underlying issue is resolved.
Note: Frequent activation of the limit control indicates an underlying issue with the HVAC system that requires investigation by a qualified technician.
5. მოვლა
The Trane Control Limit 220F is a robust component designed for long-term reliability. Regular maintenance of the overall HVAC system is recommended to ensure its proper function and longevity.
- წლიური შემოწმება: During routine HVAC system maintenance, have a qualified technician inspect the limit control for any signs of physical damage, corrosion, or loose connections.
- სისუფთავე: Ensure the area around the limit control is free from dust, debris, or obstructions that could affect its temperature sensing capabilities.
- გაყვანილობის მთლიანობა: Check that all wiring connected to the limit control is intact, not frayed, and securely fastened.
- ფუნქციონალურობის შემოწმება: While not a user-serviceable item for testing, a technician can verify its operation during system diagnostics.
Do not attempt to clean the internal components of the limit control or apply any lubricants. This can impair its function.
6. Დიაგნოსტიკა
If your HVAC unit is experiencing issues related to temperature control or unexpected shutdowns, the limit control may be involved. This section provides general troubleshooting steps. For complex issues, always consult a qualified HVAC technician.
| სიმპტომი | შესაძლო მიზეზი | რეკომენდებული მოქმედება |
|---|---|---|
| HVAC unit frequently shuts down unexpectedly. | Overheating due to restricted airflow, dirty filters, faulty blower, or other system issues causing high temperatures. | Check air filters and replace if dirty. Ensure vents are open. Inspect blower motor for proper operation. If issues persist, contact a technician to diagnose the root cause of overheating. |
| HVAC unit does not turn on (no heat/cooling). | Limit control is open (tripped) and not resetting, or it has failed. | Ensure power is off. Visually inspect the limit control for damage. A technician can test the continuity of the limit control. If it's open at normal temperatures, it may need replacement. |
| Unit runs continuously without reaching desired temperature. | Unlikely to be the limit control itself, but rather a heating element issue, thermostat problem, or other system component. | Consult the HVAC unit's service manual or a qualified technician for diagnosis. |
მნიშვნელოვანია: Do not attempt to bypass the limit control for troubleshooting. This is a critical safety device.
7. სპეციფიკაციები
| ატრიბუტი | ღირებულება |
|---|---|
| პროდუქტის დასახელება | Trane Control Limit 220F |
| ნაწილის ტიპი | Limit Switch / Temperature Control |
| გააქტიურების ტემპერატურა | 220°F (Fixed) |
| მწარმოებელი | ტრენე |
| ASIN | B0BW541NLS |
| პროდუქტის ზომები | 11 x 9 x 2 inches (approximate package dimensions) |
| ნივთის წონა | 8 ounces (approximate package weight) |
| პირველი ხელმისაწვდომი თარიღი | 18 წლის 2023 თებერვალი |

სურათი 7.1: დახრილი view of the Trane Control Limit 220F, illustrating its compact design and robust construction.
8. გარანტია და დახმარება
As a genuine OEM part, the Trane Control Limit 220F is covered by Trane's standard warranty for replacement parts. Specific warranty terms and conditions may vary. Please retain your proof of purchase.
For technical support, warranty claims, or to locate an authorized Trane service provider, please contact Trane customer service or visit the official Trane webსაიტი:
- ტრენის ოფიციალური პირი Webსაიტი: www.trane.com
- მომხმარებელთა მომსახურება: Refer to the Trane webსაიტი რეგიონალური საკონტაქტო ინფორმაციისთვის.
When contacting support, please have your product model (B0BW541NLS) and purchase date available.





