This manual provides detailed instructions for the proper use, setup, and maintenance of your ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and home use to measure blood pressure non-invasively.

რა არის ყუთში

ELKO EL-430 Sphygmomanometer components and packaging

Image showing the ELKO EL-430 Sphygmomanometer packaging and its main components: the high precision gauge, BP bulb with valve, and special design cotton cuff.

Upon opening the package, verify that all components are present and undamaged. The standard package for the ELKO EL-430 includes:

ძირითადი მახასიათებლები

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Image of the ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer, showing the large clock-face gauge, the black cotton cuff, and the inflation bulb.

დაყენება

Before taking a measurement, ensure the device is properly assembled and positioned. The EL-430 is a clock/desk type unit, designed for stable placement during use.

  1. ამოალაგე კომპონენტები: Carefully remove the sphygmomanometer, cuff, and inflation bulb from the packaging.
  2. Connect Cuff and Bulb: Ensure the cuff and inflation bulb are securely connected to the gauge via their respective tubes. The dual-tube bladder should be correctly attached.
  3. განათავსეთ მოწყობილობა: Place the main gauge unit on a stable, flat surface, such as a desk or table, at approximately heart level. The integrated basket can be used to keep the cuff and bulb organized.
  4. პაციენტის მომზადება: The patient should be seated comfortably with their arm resting on a flat surface, palm facing upwards. Ensure the arm is relaxed and at heart level. Avoid talking or moving during the measurement.

Operating Instructions: Measurement Procedures

Blood Pressure Measurement Procedures

Image illustrating the four key steps for blood pressure measurement: stethoscope placement, cuff inflation, listening for Korotkoff sounds, and controlled deflation.

არტერიული წნევის ზუსტი გაზომვისთვის მიჰყევით ამ ნაბიჯებს:

  1. Cuff Placement and Stethoscope Positioning: Wrap the cuff firmly around the upper arm, ensuring it is snug but not too tight. The lower edge of the cuff should be about 1 inch (2-3 cm) above the elbow joint. Place the stethoscope head over the main artery (brachial artery), which is typically found on the inner side of the arm, underneath the artery mark of the cuff.
  2. ინფლაცია: With the air release valve completely closed, press the inflation bulb repeatedly and continue pumping until the gauge reads a value 20-30 mmHg above your normal systolic blood pressure. If you do not know your normal systolic pressure, inflate to approximately 180-200 mmHg.
  3. Listening and Recording Systolic Pressure: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second. Listen carefully through the stethoscope. The first distinct, rhythmic sound you hear (Korotkoff sound) indicates the systolic pressure (the upper number). Note the reading on the gauge at this exact moment.
  4. Listening and Recording Diastolic Pressure: Continue to slowly deflate the cuff. The point at which the Korotkoff sounds completely disappear indicates the დიასტოლური წნევა (the lower number). Note this reading on the gauge. If the sounds become muffled but do not disappear, the muffled sound point can be considered the diastolic pressure.

არტერიული წნევის მაჩვენებლების გაგება

Blood Pressure Chart and Reading Precautions

Image displaying a blood pressure chart categorizing readings (Normal, Elevated, High Blood Pressure Stages 1 & 2, Hypertensive Crisis) and a list of conditions under which a reading should not be attempted.

Refer to the chart below for general blood pressure categories. Consult a healthcare professional for interpretation of your readings and personalized advice.

Blood Pressure Chart (mmHg)
არტერიული წნევის კატეგორიაSystolic (upper number)Diastolic (lower number)
ნორმალურინაკლებია, ვიდრე 120ნაკლებია, ვიდრე 80
ამაღლებული120 - 129 წწნაკლებია, ვიდრე 80
მაღალი არტერიული წნევა (ჰიპერტენზია) Stage 1130 - 139 წწ80 - 89 წწ
მაღალი არტერიული წნევა (ჰიპერტენზია) Stage 2140 ან უფრო მაღალი90 ან უფრო მაღალი
Hypertensive Crisis (consult your doctor immediately)180-ზე მაღალი120-ზე მაღალი

DO NOT ATTEMPT A READING...

  1. Within 1 hour of food intake.
  2. Immediately after a tea, coffee, or a smoke.
  3. Within 20 minutes of taking a bath.
  4. While talking or moving your hand/fingers.
  5. When climate is very cold.
  6. When bladder is full or you feel like discharging urine.

მოვლა და მოვლა

Proper maintenance ensures the longevity and accuracy of your sphygmomanometer.

პრობლემების მოგვარება

If you encounter issues with your ELKO EL-430, refer to the following common problems and solutions:

სპეციფიკაციები

სპეციფიკაციადეტალი
მოდელის ნომერიEL-430
ჩვენების ტიპიანალოგი
გაზომვის დიაპაზონი0 - 300 mmHg
სიზუსტე+/- 3 mmHg
მანჟეტის ტიპიLarge Cotton Cuff with Velcro Fasteners
მოყვება კომპონენტებიCuff, Gauge, Inflation Bulb with Valve
ნივთის წონა600 გ
პროდუქტის ზომები (L x W x H)14L x 14W x 18Th Centimeters
მწარმოებელიAnita Industries
წარმოშობის ქვეყანაინდოეთი
პირველი ხელმისაწვდომი თარიღი12 წლის 2024 თებერვალი

გარანტია და მხარდაჭერა

For warranty information, technical support, or service inquiries regarding your ELKO EL-430 Sphygmomanometer, please contact the manufacturer directly.

მწარმოებლის საკონტაქტო ინფორმაცია:
Anita Industries
New Delhi, India
ელფოსტა: info@elkoindia.com
ტელეფონი: +91 9911129201

Please have your model number (EL-430) and date of purchase available when contacting support.