NENEN NSX630 N TMD 630A 4-Pole 50kA

NENEN Circuit Breaker NSX630 N TMD 630A 4-Pole 50kA User Manual

Model: NSX630 N TMD 630A 4-Pole 50kA

1. შესავალი

This manual provides essential information for the safe and effective installation, operation, and maintenance of the NENEN NSX630 N TMD 630A 4-Pole 50kA Circuit Breaker. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and prevent potential hazards.

The NENEN NSX630 N TMD 630A 4-Pole 50kA Circuit Breaker is designed to provide reliable protection against overload and short circuits in industrial control electrical systems. Its robust construction ensures long-lasting performance.

2. უსაფრთხოების ინფორმაცია

გაფრთხილება: Electrical shock hazard. Only qualified personnel should install, operate, or service this equipment. Failure to follow these instructions can result in serious injury or death.

3. პროდუქტი დასრულდაview

The NENEN NSX630 N TMD 630A 4-Pole 50kA Circuit Breaker is a robust device designed for industrial applications. It features a thermal-magnetic trip unit (TMD) for comprehensive protection.

NENEN NSX630 N TMD 630A 4-Pole 50kA Circuit Breaker

სურათი 3.1: წინა view of the NENEN NSX630 N TMD 630A 4-Pole 50kA Circuit Breaker, showing the main operating handle and terminal connections.

ძირითადი მახასიათებლები:

4. დაყენება და ინსტალაცია

Before installation, ensure that the power supply to the installation area is completely disconnected and locked out. Verify that the circuit breaker's specifications match the requirements of your electrical system.

ინსტალაციის ნაბიჯები:

  1. მონტაჟი: Securely mount the circuit breaker in the designated enclosure or panel using appropriate fasteners. Ensure adequate ventilation around the device.
  2. გაყვანილობის კავშირები:
    • Connect the incoming power lines (LINE) to the upper terminals of the circuit breaker.
    • Connect the outgoing load lines (LOAD) to the lower terminals of the circuit breaker.
    • Ensure all connections are tight and free from loose strands. Refer to the product's terminal markings for correct phase sequence.
  3. ბრუნვის სპეციფიკაციები: Tighten terminal screws to the manufacturer's specified torque values to prevent overheating and ensure proper electrical contact.
  4. გადამოწმება: After wiring, visually inspect all connections for correctness and security.

შენიშვნა: Professional installation by a certified electrician is highly recommended to ensure compliance with all safety standards and regulations.

5. საოპერაციო ინსტრუქციები

The NENEN NSX630 N TMD 630A Circuit Breaker is designed for straightforward operation.

Turning On the Circuit Breaker:

  1. Ensure all downstream loads are in a safe state (e.g., turned off or disconnected if necessary).
  2. Move the operating handle to the "ON" position. The handle should latch firmly in place.
  3. Restore power to the main circuit.

Turning Off the Circuit Breaker:

  1. Move the operating handle to the "OFF" position.
  2. Verify that power to the protected circuit is disconnected before performing any work.

Resetting a Tripped Circuit Breaker:

If an overload or short circuit occurs, the circuit breaker will automatically trip to the "TRIPPED" position (often indicated by an intermediate handle position or a visual indicator).

  1. შეცდომის იდენტიფიცირება და გამოსწორება: Determine the cause of the trip (e.g., overloaded circuit, short circuit) and correct the issue.
  2. Reset Handle: Fully push the operating handle to the "OFF" position first, then move it to the "ON" position. This resets the internal tripping mechanism.
  3. If the circuit breaker trips immediately again, do not attempt to reset it repeatedly. Consult a qualified electrician to diagnose the underlying electrical fault.

6. მოვლა

Regular maintenance helps ensure the longevity and reliable operation of your NENEN circuit breaker. Always disconnect power before performing any maintenance.

7. Დიაგნოსტიკა

ეს განყოფილება იძლევა რეკომენდაციებს გავრცელებული პრობლემების შესახებ. რთული პრობლემების შემთხვევაში, მიმართეთ კვალიფიციურ ელექტრიკოსს.

პრობლემაშესაძლო მიზეზიგამოსავალი
ხშირად ითიშება ავტომატური ამომრთველი.Overload on the circuit, short circuit, or ground fault.
  • შეამცირეთ დატვირთვა წრედზე.
  • Inspect wiring and connected devices for short circuits or ground faults.
  • If the problem persists, consult an electrician.
ავტომატური ამომრთველი არ იტვირთება.Persistent fault on the circuit, internal damage to the breaker.
  • Ensure the handle is fully pushed to "OFF" before attempting to reset to "ON".
  • Verify that the fault has been cleared.
  • If unable to reset, the breaker may be damaged and require replacement by a qualified professional.
შეხებისას გამტეხი ცხელია.გადატვირთვა, ფხვიერი შეერთებები ან შიდა გაუმართაობა.
  • დაუყოვნებლივ გამორთეთ დენი.
  • Check for overload conditions.
  • Inspect and tighten all terminal connections.
  • If heating persists, replace the breaker.

8. სპეციფიკაციები

The following are the technical specifications for the NENEN NSX630 N TMD 630A 4-Pole 50kA Circuit Breaker:

9. გარანტია და მხარდაჭერა

For warranty information or technical support regarding your NENEN Circuit Breaker, please refer to the documentation provided at the point of purchase or contact your authorized NENEN distributor. Keep your purchase receipt as proof of purchase for warranty claims.

დაკავშირებული დოკუმენტები - NSX630 N TMD 630A 4-Pole 50kA

წინასწარიview ABB VD4 ვაკუუმური ამომრთველი: ტექნიკური კატალოგი და სპეციფიკაციები
გაეცანით ABB VD4 ვაკუუმურ ამომრთველს, ელექტროგამანაწილებელი სისტემების მაღალი ხარისხის გადაწყვეტას. ეს კატალოგი დეტალურად აღწერს ტექნიკურ სპეციფიკაციებს, ექსპლუატაციის პირობებს, მონტაჟსა და მოვლა-პატრონობას 12-24 კვ ძაბვის მოდელებისთვის.
წინასწარიview AEG VL Vacuum Circuit Breaker User Manual
This user manual provides comprehensive details for the AEG VL Vacuum Circuit Breaker, covering its overview, structural principles, technical specifications, dimensions, electrical schematics, installation, commissioning, operation, maintenance, transportation, storage, and spare parts. It is intended for professional electrical personnel.
წინასწარიview AEG VL 真空断路器 用户手册
AEG VL系列真空断路器的用户手册,提供产品概述、结构原理、技术参数、安装、操作、维护保养及安全指南,适用于电网设备及工矿企业动力设备。
წინასწარიview ABB TEYF3100 3-პოლური 100A ავტომატური ამომრთველის მონაცემთა ფურცელი
ABB TEYF3100-ის, 3-პოლური, 100-იანი, ტექნიკური მახასიათებლები და დეტალები Amp ჩამოსხმული კორპუსის ამომრთველი, რომელიც შექმნილია განათების პანელებისთვის. მახასიათებლები მოიცავს ჭანჭიკზე დამაგრებას, სწრაფი დამზადების/გათიშვის მექანიზმებს და სტანდარტულ გამორთვის ფუნქციებს.
წინასწარიview Eaton PDG32K0600P2YN: დენის დაცვის ავტომატური ამომრთველის სპეციფიკაციები
Eaton PDG32K0600P2YN Power Defense-ის ჩამოსხმული კორპუსის ამომრთველის დეტალური სპეციფიკაციები, რესურსები და დოკუმენტაცია, მათ შორის ტექნიკური მონაცემები, ინსტალაციის სახელმძღვანელოები და გამოყენების შენიშვნები.
წინასწარიview Legrand DPX³ 1600 S10 ელექტრონული ამომრთველების ტექნიკური მონაცემები
Legrand DPX³ 1600 S10 ელექტრონული დისპლეის ვერსიის ამომრთველების ტექნიკური სპეციფიკაციები, მახასიათებლები, ინსტალაციის სახელმძღვანელო მითითებები და მუშაობის მრუდები.