ICM CONTROLS ICM282B Fixed Speed Furnace Control Replacement Module

პროდუქტის გამოყენების ინსტრუქცია
- მხოლოდ გაწვრთნილმა პერსონალმა უნდა დაამონტაჟოს ან მომსახუროს გათბობის მოწყობილობები.
- Be sure to read and understand all precautions in the documentation, on labels, and on tags that accompany the equipment to avoid damage or personal injury.
- Use caution to avoid and control electrostatic discharge when installing and servicing the furnace.
- Follow precautions to prevent ESD from hand tools and personnel by discharging static electricity buildup to ground.
- Turn the thermostat to the OFF position or the lowest setting.
- Turn OFF the electrical and gas supply to the furnace.
- Ground yourself and handle the circuit board by the edges.
- Insert the board into the control box slots and fasten with retaining screws.
- Install the included wiring harness adapter to the existing furnace wiring harness connections.
- Connect the black wire from the furnace auxiliary junction box to L1 on the new furnace control board.
- Connect the white wire from the furnace auxiliary junction box to the Neutral spade connections.
- Connect blower motor leads as specified.
ინსტალაციის, ექსპლუატაციის და აპლიკაციის გზამკვლევი
- დამატებითი ინფორმაციისთვის ამერიკული წარმოების პროდუქტების ჩვენი სრული ასორტიმენტის შესახებ - პლუს გაყვანილობის დიაგრამები, პრობლემების მოგვარების რჩევები და სხვა, გვეწვიეთ მისამართზე www.icmcontrols.com
შესავალი
- The ICM282B fixed speed furnace control replaces the following Carrier models: CEBD431012-01A, CEPL1311012-01, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034 and 325878-751.
- The ICM282B has incorporated LED diagnostics to assist in troubleshooting.
მახასიათებლები
- Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner
- მიკროპროცესორზე დაფუძნებული
- Designed for 100% gas shut-off in case of ignition failure
- Twinning is compatible with other ICM282B boards
- საპირისპირო პოლარობის დაცვა
- Secondary brownout voltagე დაცვა
- Compatible with a 24 VAC standard thermostat
- Provides a diagnostic LED to aid in troubleshooting
სპეციფიკაციები
- Electrical Ratings: 120VAC @ 60Hz
- Ignitor: 5A resistive @ 120 VAC
- Cool Blower: 13.8 FLA, 82.8 LRA @ 120 VAC
- Heat Fan: 13.8 FLA, 82.8 LRA @ 120VAC
- Inducer Fan: 1/10 Hp @ 120 VAC
- Gas Valve: 16VA pilot duty @ 24 VAC
- Humidifier: 1A resistive @ 120 VAC
- Electric Air Cleaner: 1A resistive @ 120 VAC
უსაფრთხოების პირობები
- მხოლოდ გაწვრთნილმა პერსონალმა უნდა დაამონტაჟოს ან მომსახუროს გათბობის მოწყობილობები.
- When working with heating equipment, be sure to read and understand all precautions in the documentation, on labels, and on tags რომელიც თან ახლავს აღჭურვილობას.
- უსაფრთხოების ყველა რეკომენდაციის შეუსრულებლობამ შეიძლება გამოიწვიოს აღჭურვილობის დაზიანება, მძიმე პირადი დაზიანება ან სიკვდილი.
ელექტროსტატიკური გამონადენი (ESD) სიფრთხილის ზომები
სიფრთხილე! სიფრთხილე გამოიჩინეთ ღუმელის დამონტაჟებისა და მომსახურებისას, რათა თავიდან აიცილოთ და გააკონტროლოთ ელექტროსტატიკური გამონადენი; ESD-ს შეუძლია გავლენა მოახდინოს ელექტრონულ კომპონენტებზე. ეს სიფრთხილის ზომები უნდა დაიცვან ხელის ხელსაწყოებიდან და პერსონალისგან ელექტროსტატიკური გამონადენის თავიდან ასაცილებლად. სიფრთხილის ზომების დაცვა დაიცავს კონტროლს ESD-ისგან სტატიკური ელექტროენერგიის დაგროვების მიწაზე განტვირთვით.
- გამორთეთ მთელი ენერგია ღუმელში. არ შეეხოთ კონტროლს ან გაყვანილ სადენს, სანამ თქვენი სხეულის ელექტროსტატიკური მუხტი მიწაზე გადატვირთავთ.
- დასაბუთების მიზნით, შეახეთ ხელი და ხელსაწყოები ღუმელის სუფთა, მეტალის (შეუღებავ) ზედაპირს მართვის დაფის მახლობლად.
- შეასრულეთ ღუმელი შასის შეხების შემდეგ. თქვენი სხეული დაიტენება სტატიკური ელექტროენერგიით, როდესაც თქვენ ახვევთ ფეხებს ან მოძრაობთ, და თქვენ უნდა გადააკეთოთ საკუთარი თავი.
- გადაამაგრეთ თავი, თუ დაუსაბუთებელ ნივთებს შეეხებით.
- Before handling a new control, re-ground yourself; this will protect the control. Store used and new controls in separate containers before touching ungrounded objects.
- ESD დაზიანების თავიდან აცილება ასევე შესაძლებელია ESD სერვისის ნაკრების გამოყენებით.
Step 1: Remove Exisiting Control
სიფრთხილე! მომსახურების კონტროლისთვის და გათიშვამდე, ყველა მავთულის ეტიკეტირება. ამის შეუსრულებლობამ შეიძლება გამოიწვიოს გაყვანილობის შეცდომები, რამაც შეიძლება გამოიწვიოს საშიში ოპერაცია.
- ჩართეთ თერმოსტატი OFF პოზიციაზე ან დააყენეთ ის ყველაზე დაბალ პარამეტრზე.
- გამორთეთ ღუმელის ელექტრომომარაგება.
- Turn OFF the gas supply tothe furnace.
სიფრთხილე! გაზისა და ელექტრომომარაგების გამორთვამ შეიძლება გამოიწვიოს აფეთქება, ხანძარი, სიკვდილი ან პირადი დაზიანება. - For 80% furnaces, remove control access and blower door; for 90%furnaces, remove outer door assembly and remove the two screws from blower access panel and set aside.
- გათიშეთ თერმოსტატის სადენები და დამატენიანებელი მავთულები (თუ აღჭურვილია დამატენიანებელით).
- გათიშვის ხაზი ტtage, ჰაერის გამწმენდის ელექტრონული მავთულები (თუ აღჭურვილია) და ტრანსფორმატორის მავთულები.
- For 80% furnaces, remove retaining screws and remove furnace control board from bracket; for 90% furnaces, remove two screws from blower deck that hold the control box assembly. Lower the control box assembly. Remove retaining screw(s) from board and remove board from control box assembly.
- Remove wiring harness connectors from the circuit board.
- Examine the control and the control box to check for water stains.
- განახორციელეთ შეკეთება, თუ აღმოჩნდება წყლის გაჟონვის წყარო. დარწმუნდით, რომ შეამოწმეთ დამატენიანებლები, აორთქლების ხვეულები და სავენტილაციო სისტემები კონტროლის არეში.
Step 2: Install the New Control
- დასაბუთებული თავი. მიკროსქემის დაფის დამუშავებისას დაიჭირეთ იგი კიდეებთან.
- Insert tab(s) of board into the slots of the control box (if required).
- Fasten circuit board with retaining screw(s). Install the included wiring harness adapter to the three connections of the existing furnace wiring harness.
- A. The furnace harness 9-pin connector plugs into the mating 9-pin adapter harness connector.
- B. The furnace harness 2-pin connector plugs into the mating 2-pin adapter harness connector.
- C. The furnace harness 3-pin connector plugs into the mating 3-pin adapter harness connector.
- Connect the other end of the included adapter harness to the new furnace control board.
- A. The 11-pin connector connects to PL1 on the furnace control board.
- B. The 2-pin connector (with 2-black wires) connects to PL2 on the furnace control board.
- C. The (2) white wires connect to the 115-volt Neutral spade connections located in front of PL1 on the new furnace control board.
- Connect the transformer to the new furnace control board.
- A. Blue wire to SEC-2 terminal, located adjacent to the 3 amp დაუკრავენ
- B. Red wire to SEC-1 terminal, located adjacent to the 3 amp დაუკრავენ
- C. Black wire to PR-1 terminal, located adjacent to PL2.
- D. White wire to one of the 115-volt Neutral spade connections located in front of PL1.
სისტემის ტესტები
Step 1: Component Self Test
- Begin component test sequence by ensuring that thermostat is turned to OFF position and thermostat wires are disconnected. Turn power ON and manually close the blower door switch. With a short piece of wire, briefly short TEST/TWIN terminal to Com/24V terminal. The component test sequence follows:
- A. Status LED will flash code and will then turn ON the inducer motor.
- B. Inducer motor will run for the entire component test.
- C. Hot surface ignitor will turn ON for 15 secs.
- D. Blower motor heat speed will turn ON for 10 secs.
- E. Blower motor cool speed will turn ON for 10 secs.
- Repair, replace, or service any failing components from the component self-test. The gas valve is not energized during the self-test.
- გამორთეთ დენი.
- Release the blower door switch.
- Connect thermostat wires.
- Install blower door and access door.
- ჩართეთ დენი.
- Turn gas ON.
Step 2: Flame Sensor Operation
- Connect a DC microammeter in series with flame sensor.
- Initiate a heat call. After burners ignite and stabilize, measure flame current. Nominal flame current is between 2.0 and 3.0 microamps DC.
- If flame current reading is less than 2.0 microamps DC, either replace or remove and clean flame sensor with a fine grade steel wool.
- When the flame current falls to 0.5 microamps DC, the furnace control will lock out.
Step 3: Systems Operation
- Perform necessary safety checks. Consider flame sensor, limit switch, and vent system.
- Operate unit through a complete call for heat cycle.
- Connect the black wire from the furnace auxiliary junction box to L1 on the new furnace control board (located on the blower enable relay).
- Connect the white wire from the furnace auxiliary junction box to one of the 115-volt Neutral spade connections located in front of PL1.
- Connect the blower motor leads to the new furnace control board.
- A. Connect the white blower motor lead to the BLW connection within the group of 115-volt Neutral spade connections.
- B. Connect the blower motor heat tap to the blower relay connection marked HEAT.
- C. Connect the blower motor cool tap to the blower relay connection marked COOL.
- D. Connect the remaining blower motor leads to SPARE-1 and SPARE-2.
- Connect all accessory wires.
- For 90% furnaces, reinstall the control box assembly to the blower deck using the screws previously removed from the blower deck.
- Set blower off delay jumper located on the top-center portion of the control board. The factory default is set at 120 seconds.
- Do not connect the thermostat wires to the control board until System Tests are complete.
TWINNING INSTRUCTIONS
A 3/16” quick-connect terminal is provided on the ICM282B control board for communication between another ICM282B control board for furnace twinning.
To configure your control boards for twinning:
- Install each control board according to the installation instructions.
- Connect the TWIN terminals together.
- Connect the 24 VAC common together. (A common ground between the two furnaces is also required.)
If the 24 VAC supplies to the control are in phase, both furnaces will turn the blower on and off synchronously and at the same speed. If the 24 VAC supplies are not in phase, then neither control will respond to the thermostat commands and the status LED will flash rapidly.
პრობლემების მოგვარება
TROUBLESHOOTING ICM282B
- Each of the following status codes is a two-digit number with the first digit determined by the number of short flashes and the second digit by the number of long flashes.
| LED კოდი | სტატუსი | პრობლემების მოგვარება |
| უწყვეტი გამორთვა | Check for 115 VAC at L1 and L2, and 24 VAC at sec-1 and sec-2. | |
| უწყვეტი ჩართვა | Control has 24V power. | |
| სწრაფი ციმციმი | ხაზი ტომიtage (115V) polarity reversed, or twinning problem. | |
| 1 | Flash Brownout | ტtage at SEC1 and SEC2 is below 18 VAC |
| 11 | კომპონენტის ტესტი | Unit runs through a component self-test; however, not every input and output is tested. |
| 12 | Blower on After Power Up (115VAC OR 24VAC) | Blower runs for 90 seconds if unit is powered up during a call for heat (R-W closed). |
| 13 | Limit or Flame Roll-Out Switch Lockout | Auto reset after 3 hour. For flame roll-out switch or fuse link (see status code #33) |
| 14 | ანთების ჩაკეტვა | Lockout occurs after 4 tries. Control will auto-reset after 3 hours (see status code #34 below) |
| 21 | Gas Heating Lockout | Control will NOT auto-reset. Check for: 1) a stuck gas valve relay on the control, or 2) a miswire to gas valve circuit. |
| 22 | Abnormal Flame-Proving Signal | Flame is present while gas valve is de-energized. Inducer will run until the fault is cleared. Check for
1) a stuck gas valve or 2) a leaky gas valve. |
| 23 | Pressure Switch Did Not Open | Check for 1) obstructed pressure tubing or 2) a defective pressure switch (stuck in closed position). |
| 31 | Pressure, Draft Safeguard, Auxiliary-Limit (when used), Or Blocked Vent Shutoff (when used) Switch did not Close or Reopen | If open longer than 5 minutes, the board will shut off the inducer for 15 minutes before retry.
შეამოწმეთ: . Proper vent sizing and condensate pitch or sag . Defective inducer motor or start capacitor . Vent restriction or high winds . Defective pressure switch or connection. If it opens after trial for ignition period, the blower will come on for 90 90-second recycle delay . წვის ჰაერის არასაკმარისი მიწოდება . გათიშული ან დაბრკოლებული წნევის მილები . დაბალი ინდუქტორის მოცtage |
| 33 | Limit or Flame Roll-Out Switch is Open | If open longer than 3 minutes, code changes to #13.
შეამოწმეთ: . Defective blower motor or start capacitor . ფხვიერი აფეთქების ბორბალი . წვის ჰაერის არასაკმარისი მიწოდება . Flame roll-out switch or fuse link . ჭუჭყიანი ფილტრი ან შეზღუდული სადინარში სისტემა . დეფექტური გადამრთველი ან კავშირები . Open flame roll-out switch, or fuse link. Manual reset or replace. |
| 34 | ანთების უკმარისობა | Control will try three more times before a lockout #14 occurs. If the flame signal is lost after the trial for the ignition period. Blower will come on for 90 90-second recycle delay.
შეამოწმეთ: . Oxide buildup on flame sensor (clean with fine sandpaper) . სათანადო ალი მიკროamps (when the flame current falls to 0.5 microamps DC, the furnace control will lock out) . Green wire MUST be connected to the furnace sheet metal . ცეცხლის არასაკმარისი გადატანა ან უხეში აალება . გაზის სარქველი გამორთულია . მექანიკური გამორთვის სარქველი . Low inlet gas pressure |
CONNECTION AND WIRING DIAGRAM

PIN OUT FOR 9 PIN TO 11 PIN ADAPTOR HARNESS

გარანტია
სიცოცხლის შეზღუდული დაცვის გარანტია
- საგარანტიო ინფორმაციისა და რეგისტრაციისთვის გთხოვთ ეწვიოთ www.icmcontrols.com და დააჭირეთ გარანტიის რეგისტრაციას.
კონტაქტი
- 7313 William Barry Blvd., North Syracuse, NY 13212 www.icmcontrols.com
FAQ
Q: Can I install the ICM282B control without professional help?
A: It is recommended that only trained personnel handle the installation and servicing of heating equipment to ensure safety and proper functioning.
Q: რა უნდა გავაკეთო, თუ ინსტალაციის დროს გაყვანილობის შეცდომებს შევხვდები?
A: Labeling wires before disconnection is crucial to avoid wiring errors. If errors occur, refer to the manual for guidance or seek professional assistance to rectify the issue.
დოკუმენტები / რესურსები
![]() |
ICM CONTROLS ICM282B Fixed Speed Furnace Control Replacement Module [pdf] ინსტალაციის სახელმძღვანელო ICM282B, CEBD431012-01A, CEPL1311012-01, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034, 325878-751, ICM282B Fixed Speed Furnace Control Replacement Module, ICM282B, Fixed Speed Furnace Control Replacement Module, Speed Furnace Control Replacement Module, Furnace Control Replacement Module, Control Replacement Module, Replacement Module |